Introduction
The Water Velocity application estimates stream velocity at a river or stream crossing. It uses the velocity to check the hydrodynamic loads on an exposed or submerged liquid pipeline span. Water velocity drives three things in a crossing design:
- Drag and lift forces on a submerged span. These are added to the loading in the Pipe Span & Support Analysis application.
- Scour and erosion at the supports and banks. These are checked against permissible velocities for the channel soil.
- Vortex-induced vibration. Velocity is the key input to the Critical Pipeline Span Length application.
Calculation Methodology
Step 1: Variable Definition
Where:
π β Mean Stream Velocity (ft/s)
π β Manning’s Roughness Coefficient
π
β Hydraulic Radius, A/P (ft)
π΄ β Flow Cross-Sectional Area (ft2)
πw β Wetted Perimeter (ft)
π β Channel Slope (ft/ft)
π β Flow Rate (ft3/s)
Οw β Water Density (slug/ft3)
π· β Pipe Outside Diameter including coating (ft)
CD, CL β Drag and Lift Coefficients
Step 2: Calculate Stream Velocity (Manning’s Equation)
V=\frac{1.486}{n}R^{2/3}S^{1/2},\quad R=\frac{A}{P_w},\quad Q=VAStep 3: Compare with Permissible Velocity
Compare the calculated velocity with the permissible (non-erosive) velocity for the channel soil (USDA-SCS). Where the velocity is higher, expect scour at the supports. Found the supports below the design scour depth (FHWA HEC-18) or protect the channel.
Step 4: Calculate Drag and Lift Forces per Unit Length
F_D=\frac{1}{2}\rho_w C_D D V^2F_L=\frac{1}{2}\rho_w C_L D V^2CD and CL depend on the pipe surface roughness, the Reynolds number and the gap between the pipe and the streambed. The drag force acts horizontally and the lift force acts upward.
Step 5: Check Submerged Weight (Flotation)
W_{sub}=W_{pipe}+W_{coating}+W_{contents}-\rho_w g\frac{\pi D^2}{4}-F_LA negative submerged weight means the pipe will float or lift off its supports. Add a concrete weight coating, set-on weights or anchors.
Case Guide
Part 1: Create Case
- Select the Water Velocity (Liquid) application from the Design & Stress Analysis Module.
- To create a new case, click the βAdd Caseβ button.
- Enter Case Name, Location, Date and any necessary notes.
- Fill out all required Parameters.
- Make sure the values you are inputting are in the correct units.
- Click the CALCULATE button to overview results.
Input Parameters
- Channel Geometry (bottom width, side slopes, flow depth) or Flow Area and Wetted Perimeter
- Channel Slope (ft/ft)
- Manning’s Roughness Coefficient, n
- Channel Soil Type
- Pipe Outside Diameter (in)
- Coating Thickness and Unit Weight
- Water Unit Weight (pcf)
- Drag and Lift Coefficients
- Content Unit Weight

Part 2: Outputs/Reports
- If you need to modify an input parameter, click the CALCULATE button after the change.
- To SAVE, fill out all required case details then click the SAVE button.
- To rename an existing file, click the SAVE As button. Provide all case info then click SAVE.
- To generate a REPORT, click the REPORT button.
- The user may export the Case/Report by clicking the Export to Excel icon.
- To delete a case, click the DELETE icon near the top of the widget.
Results
- Hydraulic Radius (ft)
- Mean Stream Velocity (ft/s)
- Flow Rate (ft3/s)
- Permissible Velocity for Channel Soil and Erosion Check
- Drag Force per Unit Length (lb/ft)
- Lift Force per Unit Length (lb/ft)
- Submerged Weight / Flotation Check

References
- USDA-SCS Modified β Permissible Velocity of Water and Soil Erodibility
- FHWA-HEC-18 β Evaluating Scour at Bridges
- FHWA-HEC-20 β Stream Stability at Highway Structures
- DNV-RP-F109 β On-Bottom Stability Design of Submarine Pipelines
- ASME B31.4 β Pipeline Transportation Systems for Liquids and Slurries
- Pipeline Rules of Thumb Handbook
FAQ
-
Restrained versus Unrestrained Pipe (Difference in Gas vs. Liquid)?
ASME B31.4 liquid and B31.8 gas codes include calculations for the net longitudinal compressive stress that must be applied only for a restrained line that equates to a low (less than 2%) longitudinal strain. This stress status is characteristic to underground pipelines located some distance away from above ground piping facilities.
Unrestrained lines means those above ground sections of piping without axial restraint as with buried pipe with soil.Β Β In others words the soil exerts substantial axial restraint, but not fully restrained. Check Out
-
What is the Maximum Span Length of rev1?
Regarding span factors with and without water are based on bending stress and deflection.Β Larger diameter pipe spansΒ require saddles for stability. Many standards that require pipes to be filled with water are based on bending and shear stresses not to exceed 1,500 psi and a deflection between supports not exceed 0.1 inches. Check Out
-
What is the model used for Thrust at Blow-Off?