Resistance to Earth of an Impressed Anode Ground Bed
This calculation is used to calculate rectifier and ground bed sizing to protect large underground piping systems such as pump/compressor stations and large transmission piping systems.
These systems are not practical for 1 amp or less with low driving voltages. In addition, impressed current system require an AC power source to operate a rectifier to convert AC to DC power.
R — Total ground bed to earth resistance(0hms)
r — Resistance to earth of one installed anode (0hm/ cm)
ρ — Actual soil resitivity (0hm / cm)
K — Correction factor for anode grouping
N — Number of anodes
Input Parameters
- To create a new case, click the “Add Case” button
- Select the Resistance to Earth of an Impressed Anode Ground Bed application from the Cathodic Protection module list.
- Enter Case Name, Location, Date and any necessary notes.
- Fill out all required fields.
- Make sure the values you are inputting are in the correct units.
- Click the CALCULATE button.
- Resistance to Earth for One Installed Anode
- Actual Soil Resistivity
- Correction Factor for Anode Grouping
- Number of Anodes
Outputs/Reports
- View the results.
- If an input parameter needs to be edited be sure to hit the CALCULATE button after the change.
- To SAVE, fill out all required case details then click the SAVE button.
- To rename an existing file, click the SAVE As button. Provide all case info then click SAVE.
- To generate a REPORT, click the REPORT button.
- The user may export the Case/Report by clicking the Export to Excel/PowerPoint icon.
- To delete a case, click the DELETE icon near the top of the widget.
- Total Ground Bed to Earth Resistance (See Single Horizontal Anode and Multiple Horizontal Anodes) This application has been replaced.
Related Links
Table of Contents
Table of Pages
Table of Contents
- Pipeline HUB User Resources
- AC Mitigation PowerTool
- API Inspector's Toolbox
- Horizontal Directional Drilling PowerTool
- Crossings Workflow
- Hydrotest PowerTool
- Pipeline Toolbox
- Encroachment Manager
- PRCI AC Mitigation Toolbox
- PRCI RSTRENG
- RSTRENG+
- Ad-hoc Analysis
- Database Import
- Data Availability Dashboard
- ESRI Map
- Report Builder
- Crossings Workflow
- Hydrotest PowerTool
- Investigative Dig PowerTool
- Hydraulics PowerTool
- External Corrosion Direct Assessment Procedure - RSTRENG
- Canvas
- Definitions
- Pipe Schedule and Specifications Tables