Introduction
As water (or wind) flows past a pipe, vortices shed alternately from each side and create a cyclic force. When the vortex shedding frequency approaches the natural frequency of the span, the pipe can lock in and vibrate at large amplitude. This vortex-induced vibration (VIV) can cause fatigue damage quickly.
The Critical Pipeline Span Length application calculates the free-span length of a gas line at which VIV starts. Keep the actual span shorter than the critical length, and also within the maximum span from the Pipe Span & Support Analysis application. The shorter of the two governs.
Calculation Methodology
Step 1: Variable Definition
Where:
π β Current (or Wind) Velocity (ft/s)
π· β Pipe Outside Diameter including coating (ft)
St β Strouhal Number (β 0.2 for a circular cylinder)
fs β Vortex Shedding Frequency (Hz)
fn β Natural Frequency of the Span (Hz)
πΆ β End Condition Constant
πΈ β Modulus of Elasticity (psi)
πΌ β Moment of Inertia (in4)
me β Effective Mass per Unit Length (pipe + coating + contents + added mass)
Ca β Added Mass Coefficient (β 1.0)
Lc β Critical Span Length (ft)
Step 2: Calculate Vortex Shedding Frequency
f_s=\frac{S_t\,V}{D}Step 3: Calculate Effective Mass
m_e=m_{pipe}+m_{coating}+m_{contents}+C_a\,\rho_w\frac{\pi D^2}{4}Step 4: Calculate Natural Frequency of the Span
f_n=\frac{C}{2\pi}\sqrt{\frac{EI}{m_e L^4}}| End condition | C |
|---|---|
| Pinned β Pinned | 9.87 |
| Fixed β Pinned | 15.4 |
| Fixed β Fixed | 22.4 |
Step 5: Solve for Critical Span Length
Set the natural frequency equal to the vortex shedding frequency and solve for L:
L_c=\sqrt{\frac{C}{2\pi f_s}\sqrt{\frac{EI}{m_e}}}Spans longer than Lc have a natural frequency below the shedding frequency and are susceptible to lock-in. Operators often apply a margin, keeping fn above fs by a factor, or use the reduced-velocity screening criteria of DNV-RP-F105.
Case Guide
Part 1: Create Case
- Select the Critical Pipeline Span Length (Gas) application from the Design & Stress Analysis Module.
- To create a new case, click the βAdd Caseβ button.
- Enter Case Name, Location, Date and any necessary notes.
- Fill out all required Parameters.
- Make sure the values you are inputting are in the correct units.
- Click the CALCULATE button to overview results.
Input Parameters
- Outside Diameter (in)
- Wall Thickness (in)
- Coating Thickness (in) and Unit Weight (pcf)
- Content Unit Weight (pcf)
- Modulus of Elasticity (psi)
- End Condition
- Current / Water Velocity (ft/s)
- Strouhal Number
- Added Mass Coefficient
- Water Unit Weight (pcf)


Part 2: Outputs/Reports
- If you need to modify an input parameter, click the CALCULATE button after the change.
- To SAVE, fill out all required case details then click the SAVE button.
- To rename an existing file, click the SAVE As button. Provide all case info then click SAVE.
- To generate a REPORT, click the REPORT button.
- The user may export the Case/Report by clicking the Export to Excel icon.
- To delete a case, click the DELETE icon near the top of the widget.
Results
- Moment of Inertia (in4)
- Effective Mass per Unit Length
- Vortex Shedding Frequency (Hz)
- Natural Frequency of Span (Hz)
- Critical Span Length (ft)

References
- DNV-RP-F105 β Free Spanning Pipelines
- ASME B31.8 β Gas Transmission and Distribution Piping Systems
- API 5L β Specification for Line Pipe
- Blevins, R.D. β Flow-Induced Vibration
- Pipeline Rules of Thumb Handbook
FAQ
-
Restrained versus Unrestrained Pipe (Difference in Gas vs. Liquid)?
ASME B31.4 liquid and B31.8 gas codes include calculations for the net longitudinal compressive stress that must be applied only for a restrained line that equates to a low (less than 2%) longitudinal strain. This stress status is characteristic to underground pipelines located some distance away from above ground piping facilities.
Unrestrained lines means those above ground sections of piping without axial restraint as with buried pipe with soil.Β Β In others words the soil exerts substantial axial restraint, but not fully restrained. Check Out
-
What is the Maximum Span Length of rev1?
Regarding span factors with and without water are based on bending stress and deflection.Β Larger diameter pipe spansΒ require saddles for stability. Many standards that require pipes to be filled with water are based on bending and shear stresses not to exceed 1,500 psi and a deflection between supports not exceed 0.1 inches. Check Out
-
What is the model used for Thrust at Blow-Off?